CAB Apollo 1 User Manual Page 16

  • Download
  • Add to my manuals
  • Print
  • Page
    / 33
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 15
ENG-15cab - Produkttechnik GmbH
Setup
Using the setup mode, the configuration of the Apollo may be customized to suit
specific requirements. Initial setup should be performed when operating the printer
for the first time. Changes which become necessary to process different print jobs,
e.g. when different materials are used, can mostly be accomplished by changing
the software settings.
Start of Setup Mode
This mode is initiated by either simultaneously pressing the key and the
key when switching on the printer and keep them pressed down until the
system test is completed, or in ONLINE mode, press the same two keys down for
at least 5 seconds.
Each time a parameter setting has been changed, there will be a request for
confirmation. There will not be a general request before leaving the setup mode.
Leaving the Setup Mode
The setup mode can be left at any point by pressing the key. The confirmed
parameters will be saved.
If an already confirmed setting is not desired any more, switch off the printer during
the setup mode to cancel changes.
Restore the Default Setup
To return to the original factory default settings, press all three keys, the key,
the key, and the key simultaneously and keep them pressed down until
the display shows "--- RESTORE ---".
ONL key Stores the chosen settings of the setup parameters and
completes the SETUP mode.
(i.e. switch into ONLINE mode/ LED ONL on)
FF key Skips to next setup parameter.
Reduces numerical setup values.
CAN key Skips to previous setup parameter.
Increases numerical setup values.
PSE key Confirms selected settings for parameters.
Function of the Keys in the Setup Mode