CAB Apollo 1 User Manual Page 25

  • Download
  • Add to my manuals
  • Print
  • Page
    / 33
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 24
cab - Produkttechnik GmbHENG-24
Montage des Spendesensors
43 5 6
2
1
F
Present Sensor
The optional present sensor in connection with printers with internal rewinder
allows for on-demand label dispensing. That means, the labels are removed from
the silicon liner immediately after printing, and then available in a dis-pense
position ready for further processing.
The present sensor (2) consists of two components, the dispense edge (18) and
the present sensor photocell (6). The presence of a label (19) in dispense position
is observed by the photocell. Through its connection to the peripheral port of the
Apollo, the signal pauses the print of the next label until the label in the dispense
position is removed.
Note : When editing or creating labels in demand mode, make sure that the part of
the label which lies directly underneath the photocell is only colored (black) to a
maximum of 50%. Higher blackening/ density print may cause malfunctions of the
sensor.
The Apollo is generally shipped with the tear-off plate (1) mounted. When
operating in dispense mode, the tear-off plate has to be replaced with the present
sensor (2) :
1. Turn lever (4) counter-clockwise until it stops.
2. Remove the tear-off plate (1) from the mounting holes (3).
3. Slide the present sensor (2) into the mounting holes (3).
4. Turn lever (4) clockwise until it stops.
5. Connect the cable (5) of the present sensor (6) to the 15 pin peripheral port of
the Apollo.
Page view 24
1 2 ... 20 21 22 23 24 25 26 27 28 29 30 31 32 33

Comments to this Manuals

No comments